ECONOMIC MODEL & OPERATIONS

Measure value. Verify results.

Evaluate each project using measured energy, resource availability and service performance. Compare a documented baseline with observed results under the same operating boundary. No fixed returns or financialized compute assets are implied.

Concept of operators reviewing energy and compute performance · AI concept · Not a project photograph or product specificationAI concept · Not a project photograph or product specification
Open image in a new window
ENGINEERING / INTERACTIVE MODEL

24-hour compute-power model

Illustrative model, not live data, a DCP benchmark or a return promise. Compare power, grid energy and electricity cost at equal daily work.

Compute energy (unchanged)

480 kWh

Scheduled grid energy

1,788 kWh

Energy-charge difference

81.6 CNY

Grid peak (before → after)

125 → 114 kW

Site power and solar output / kW
OriginalScheduledSolar

Swipe the chart or use the hour slider above to inspect values.

05010015020000:0006:0012:0018:0023:00160 kW00:00 Original 90 kW / Scheduled 114 kW / Solar 0 kW01:00 Original 90 kW / Scheduled 114 kW / Solar 0 kW02:00 Original 90 kW / Scheduled 114 kW / Solar 0 kW03:00 Original 90 kW / Scheduled 114 kW / Solar 0 kW04:00 Original 90 kW / Scheduled 114 kW / Solar 0 kW05:00 Original 90 kW / Scheduled 114 kW / Solar 0 kW06:00 Original 90 kW / Scheduled 114 kW / Solar 0 kW07:00 Original 90 kW / Scheduled 78 kW / Solar 26 kW08:00 Original 115 kW / Scheduled 103 kW / Solar 50 kW09:00 Original 115 kW / Scheduled 103 kW / Solar 71 kW10:00 Original 115 kW / Scheduled 103 kW / Solar 87 kW11:00 Original 115 kW / Scheduled 103 kW / Solar 97 kW12:00 Original 115 kW / Scheduled 103 kW / Solar 100 kW13:00 Original 115 kW / Scheduled 103 kW / Solar 97 kW14:00 Original 115 kW / Scheduled 103 kW / Solar 87 kW15:00 Original 115 kW / Scheduled 103 kW / Solar 71 kW16:00 Original 115 kW / Scheduled 103 kW / Solar 50 kW17:00 Original 115 kW / Scheduled 103 kW / Solar 26 kW18:00 Original 125 kW / Scheduled 113 kW / Solar 0 kW19:00 Original 125 kW / Scheduled 113 kW / Solar 0 kW20:00 Original 125 kW / Scheduled 113 kW / Solar 0 kW21:00 Original 125 kW / Scheduled 113 kW / Solar 0 kW22:00 Original 90 kW / Scheduled 78 kW / Solar 0 kW23:00 Original 90 kW / Scheduled 114 kW / Solar 0 kW

12:00 · Original 115 kW · Scheduled 103 kW · Solar 100 kW

Hourly grid import / kW
OriginalScheduled

Swipe the chart or use the hour slider above to inspect values.

05010015020000:0006:0012:0018:0023:0000:00 Original 90 kW / Scheduled 114 kW01:00 Original 90 kW / Scheduled 114 kW02:00 Original 90 kW / Scheduled 114 kW03:00 Original 90 kW / Scheduled 114 kW04:00 Original 90 kW / Scheduled 114 kW05:00 Original 90 kW / Scheduled 114 kW06:00 Original 90 kW / Scheduled 114 kW07:00 Original 64 kW / Scheduled 52 kW08:00 Original 65 kW / Scheduled 53 kW09:00 Original 44 kW / Scheduled 32 kW10:00 Original 28 kW / Scheduled 16 kW11:00 Original 18 kW / Scheduled 6 kW12:00 Original 15 kW / Scheduled 3 kW13:00 Original 18 kW / Scheduled 6 kW14:00 Original 28 kW / Scheduled 16 kW15:00 Original 44 kW / Scheduled 32 kW16:00 Original 65 kW / Scheduled 53 kW17:00 Original 89 kW / Scheduled 77 kW18:00 Original 125 kW / Scheduled 113 kW19:00 Original 125 kW / Scheduled 113 kW20:00 Original 125 kW / Scheduled 113 kW21:00 Original 125 kW / Scheduled 113 kW22:00 Original 90 kW / Scheduled 78 kW23:00 Original 90 kW / Scheduled 114 kW

12:00 · Original 15 kW · Scheduled 3 kW

Daily energy charge / CNY
Original1,271.2
Scheduled1,189.6
02,400 CNY

Same tariffs and daily energy; grid energy charges only.

Scheduled energy supply / kWh
Grid
1,788 kWh
On-site solar
762 kWh
Total site energy
2,550 kWh

Solar consumed + grid imports = site demand. Surplus solar earns no revenue in this model.

Assumptions, limitations and hourly data

Synthetic day, 1-hour steps. Fixed load: 95 kW at 08–17, 105 kW at 18–21, otherwise 70 kW. Original compute: 20 kW × 24 h. Movable work is ready at 00:00 and due by 24:00. Site limit: 160 kW. Assign 1 kWh increments by marginal grid cost. Illustrative tariffs: 0.4 at 00–06 and 23, 1.1 at 17–21, otherwise 0.7 CNY/kWh, not a regional tariff. Excludes migration overhead, demand charges, storage, depreciation, taxes, export revenue and emissions. Peak reduction is not the objective; grid peak may increase. Solar follows a synthetic sine curve.

Illustrative raw data · kW / CNY per kWh
HourOriginalScheduledSolarGrid·beforeGrid·afterTariff
0901140901140.4
1901140901140.4
2901140901140.4
3901140901140.4
4901140901140.4
5901140901140.4
6901140901140.4
790782664520.7
81151035065530.7
91151037144320.7
101151038728160.7
11115103971860.7
121151031001530.7
13115103971860.7
141151038728160.7
151151037144320.7
161151035065530.7
171151032689771.1
1812511301251131.1
1912511301251131.1
2012511301251131.1
2112511301251131.1
229078090780.7
23901140901140.4
SYSTEM PATH

A clear path from inputs to evidence.

01 / Energy value

Use load forecasts, demand management and equipment analysis to identify efficiency opportunities. Recommendations depend on local tariffs, equipment constraints and authorized operating windows.

Peak and off-peak demand
Demand management
Storage availability
Energy and carbon records
02 / Compute value

Place eligible inference, caching, retrieval and lightweight tasks near their data sources. Evaluate network transfer, latency and resource use before deciding which workloads to move.

Local task share
Node utilization
Network latency
Energy per task
03 / Operating value

Track device health, available capacity, response records, maintenance and service levels. Use the evidence for capacity planning and project-level cost allocation.

Equipment availability
Dispatchable capacity
Maintenance closure
Project cost accounting
COORDINATION ARCHITECTURE

Clear responsibilities. Coordinated operation.

01
Metering and site state
02
Energy and compute metrics
03
Project cost model
04
Service evaluation
05
Customer reports and audits

Agree on equipment, interfaces, retention periods, approvals and operating metrics at project initiation. Performance is verified through site measurements and acceptance testing.